PMSA003I: add support for driving SET pin low while not actively taking a telemetry reading (#6569)
* support manually shutting off power to the PMSA003I sensor when we aren't doing a telemetry reading * add comment about PMSA003I_WARMUP_MS to AirQualityTelemetry.cpp * fix typos, use arduino gpio defines instead of magic numbers * support manually shutting off power to the PMSA003I sensor when we aren't doing a telemetry reading * add comment about PMSA003I_WARMUP_MS to AirQualityTelemetry.cpp * fix typos, use arduino gpio defines instead of magic numbers * RAK4631: add PMSA003I_ENABLE_PIN define * fix indentation --------- Co-authored-by: Ben Meadors <benmmeadors@gmail.com>
This commit is contained in:
co-authored by
GitHub
Ben Meadors
parent
b4e8f7dbb6
commit
72eae42b81
@@ -197,6 +197,12 @@ SO GPIO 39/TXEN MAY NOT BE DEFINED FOR SUCCESSFUL OPERATION OF THE SX1262 - TG
|
||||
|
||||
*/
|
||||
|
||||
// configure the SET pin on the RAK12039 sensor board to disable the sensor while not reading
|
||||
// air quality telemetry. PIN_NFC2 doesn't seem to be used anywhere else in the codebase, but if
|
||||
// you're having problems with your node behaving weirdly when a RAK12039 board isn't connected,
|
||||
// try disabling this.
|
||||
#define PMSA003I_ENABLE_PIN PIN_NFC2
|
||||
|
||||
#define DETECTION_SENSOR_EN 4
|
||||
|
||||
#define USE_SX1262
|
||||
|
||||
Reference in New Issue
Block a user